Switching Mode Power Supply (DIN series) m_series_language_245094

Part Number

Configured Part Number is shown.

Part Number
DR-15-5
DR-15-12
DR-15-24
DR-30-24
DR-60-24
DR-100-12
DR-100-24
MDR-10-5
MDR-10-12
MDR-10-24
MDR-20-5
MDR-20-12
MDR-20-24
MDR-40-12
MDR-40-24
MDR-60-12
MDR-60-24
MDR-100-12
MDR-100-24
SDR-120-24
SDR-240-24
SDR-480-24
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship m_series_spec_item_renamed_language_6483281
(W)
m_series_spec_item_renamed_language_6483285 m_series_spec_item_renamed_language_6483287
(A)
m_series_spec_item_renamed_language_6483303
(mm)
m_series_spec_item_renamed_language_6483305
(mm)
m_series_spec_item_renamed_language_6483307
(mm)
m_series_spec_item_renamed_language_6483233
(A m_spec_item_language_77968)
m_series_spec_item_renamed_language_6483235
(A m_spec_item_language_77970)
m_series_spec_item_renamed_language_6483237
(A m_spec_item_language_77972)
m_series_spec_item_renamed_language_6483255
(m_spec_item_language_365631)
m_series_spec_item_renamed_language_6483257
(m_spec_item_language_365633)
m_series_spec_item_renamed_language_6483259
(m_spec_item_language_365635)
m_series_spec_item_renamed_language_6483263
(m_spec_item_language_365639)
m_series_spec_item_renamed_language_6483265
(m_spec_item_language_365641)
m_series_spec_item_renamed_language_6483267
(m_spec_item_language_365643)
m_series_spec_item_renamed_language_6483269
(m_spec_item_language_365645)
m_series_spec_item_renamed_language_6483271
(m_spec_item_language_365647)
m_series_spec_item_renamed_language_6483273
(m_spec_item_language_365649)
m_series_spec_item_renamed_language_6483275
(m_spec_item_language_365651)

336,202 IDR

1 Piece(s) 7 Day(s) or more 15DC5V2.425 ~ 9325 ~ 9356--2.485~264VAC; 120~370VDCCold start, 65A at 230VAC±10% rated output voltage77.0%--I/P-O/P: 3kVAC-20~+60°C (refer to output load derating curve)UL60950-1, TUV60950-1 approvedEN55022 class B, EN61000-3-2,3, EN61000-6-2, EN61000-4-2,3,4,5,6,8,11, EN61204-3

336,202 IDR

1 Piece(s) 7 Day(s) or more 15DC12V1.2525 ~ 9325 ~ 9356-1.25-85~264VAC; 120~370VDCCold start, 65A at 230VAC±10% rated output voltage84.0%--I/P-O/P: 3kVAC-20~+60°C (refer to output load derating curve)UL60950-1, TUV60950-1 approvedEN55022 class B, EN61000-3-2,3, EN61000-6-2, EN61000-4-2,3,4,5,6,8,11, EN61204-3

336,202 IDR

1 Piece(s) 7 Day(s) or more 15 ~ 15.2DC24V0.6325 ~ 9325 ~ 93560.63--85~264VAC; 120~370VDCCold start, 65A at 230VAC±10% rated output voltage85.0%--I/P-O/P: 3kVAC-20~+60°C (refer to output load derating curve)UL60950-1, TUV60950-1 approvedEN55022 class B, EN61000-3-2,3, EN61000-6-2, EN61000-4-2,3,4,5,6,8,11, EN61204-3

410,465 IDR

1 Piece(s) 7 Day(s) or more 30 ~ 36DC24V1.578 ~ 9378 ~ 93561.5--85~264VAC; 120~370VDCCold start, 30A at 230VAC±10% rated output voltage83%--I/P-O/P: 3kVAC-20~+60°C (refer to output load derating curve)UL60950-1, TUV60950-1 approvedEN55022 class B, EN61000-3-2,3, EN61000-6-2, EN61000-4-2,3,4,5,6,8,11, EN61204-3

524,688 IDR

1 Piece(s) 7 Day(s) or more 60DC24V2.578 ~ 9378 ~ 93562.5--88~264VAC; 124~370VDCCold start, 36A at 230VAC±10% rated output voltage84%--I/P-O/P: 3kVAC-20~+60°C (refer to output load derating curve)UL60950-1, TUV60950-1 approvedEN55022 class B, EN61000-3-2,3, EN61000-6-2, EN61000-4-2,3,4,5,6,8,11, EN61204-3

714,078 IDR

1 Piece(s) 7 Day(s) or more 100DC12V7.593 ~ 10093 ~ 10056-7.5-88~264VAC; 124~370VDCCold start, 45A at 230VAC12V: 12~15V, 15V: 15~18V, 24V: 24~29V87%--I/P-O/P: 3kVAC-20~+60°C (refer to output load derating curve)UL60950-1, TUV60950-1 approvedEN55022 class B, EN61000-3-2,3, EN61000-6-2, EN61000-4-2,3,4,5,6,8,11, EN61204-3

714,078 IDR

1 Piece(s) 7 Day(s) or more 100 ~ 100.8DC24V4.293 ~ 10093 ~ 100564.2--88~264VAC; 124~370VDCCold start, 45A at 230VAC12V: 12~15V, 15V: 15~18V, 24V: 24~29V89%--I/P-O/P: 3kVAC-20~+60°C (refer to output load derating curve)UL60950-1, TUV60950-1 approvedEN55022 class B, EN61000-3-2,3, EN61000-6-2, EN61000-4-2,3,4,5,6,8,11, EN61204-3

354,146 IDR

1 Piece(s) 7 Day(s) or more 10DC5V222.5 ~ 9022.5 ~ 90100--285~264VAC; 120~370VDCCold start, 35A at 115VAC, 70A at 230VACFixed77%>105% hiccup mode, auto-recovery115%~135% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

354,146 IDR

1 Piece(s) 7 Day(s) or more 10DC12V0.8422.5 ~ 9022.5 ~ 90100-0.84-85~264VAC; 120~370VDCCold start, 35A at 115VAC, 70A at 230VACFixed81%>105% hiccup mode, auto-recovery115%~135% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

354,146 IDR

1 Piece(s) 7 Day(s) or more 10DC24V0.4222.5 ~ 9022.5 ~ 901000.42--85~264VAC; 120~370VDCCold start, 35A at 115VAC, 70A at 230VACFixed84%>105% hiccup mode, auto-recovery115%~135% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

402,439 IDR

1 Piece(s) 7 Day(s) or more 20DC5V322.5 ~ 9022.5 ~ 90100--385~264VAC; 120~370VDCCold start, 20A at 115VAC, 40A at 230VAC±10% rated output voltage76%105%~160% constant current limiting, auto-recovery115%~135% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

402,439 IDR

1 Piece(s) 7 Day(s) or more 20DC12V1.6722.5 ~ 9022.5 ~ 90100-1.67-85~264VAC; 120~370VDCCold start, 20A at 115VAC, 40A at 230VAC±10% rated output voltage80%105%~160% constant current limiting, auto-recovery115%~135% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

402,439 IDR

1 Piece(s) 7 Day(s) or more 20 ~ 24DC24V122.5 ~ 9022.5 ~ 901001--85~264VAC; 120~370VDCCold start, 20A at 115VAC, 40A at 230VAC±10% rated output voltage84%105%~160% constant current limiting, auto-recovery115%~135% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

482,926 IDR

1 Piece(s) 7 Day(s) or more 40DC12V3.3340 ~ 9040 ~ 90100-3.33-85~264VAC; 120~370VDCCold start, 30A at 115VAC, 60A at 230VAC0~+20% rated output voltage86%105%~150% constant current limiting, auto-recovery125%~150% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

482,926 IDR

1 Piece(s) 7 Day(s) or more 40 ~ 40.8DC24V1.740 ~ 9040 ~ 901001.7--85~264VAC; 120~370VDCCold start, 30A at 115VAC, 60A at 230VAC0~+20% rated output voltage88%105%~150% constant current limiting, auto-recovery125%~150% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

547,317 IDR

1 Piece(s) 7 Day(s) or more 60DC12V540 ~ 9040 ~ 90100-5-85~264VAC; 120~370VDCCold start, 30A at 115VAC, 60A at 230VAC0~+20% rated output voltage86%105%~150% constant current limiting, auto-recovery125%~150% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

547,317 IDR

1 Piece(s) 7 Day(s) or more 60DC24V2.540 ~ 9040 ~ 901002.5--85~264VAC; 120~370VDCCold start, 30A at 115VAC, 60A at 230VAC0~+20% rated output voltage88%105%~150% constant current limiting, auto-recovery125%~150% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-20~+70°C (refer to output derating curve)UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

853,171 IDR

1 Piece(s) 7 Day(s) or more 100DC12V7.555 ~ 9055 ~ 90100-7.5-85~264VAC; 120~370VDCCold start, 30A at 115VAC, 60A at 230VAC0~+20% rated output voltage83%105%~150% constant current limiting, auto-recovery125%~150% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-10~+60°CUL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

853,171 IDR

1 Piece(s) 7 Day(s) or more 96 ~ 100DC24V455 ~ 9055 ~ 901004--85~264VAC; 120~370VDCCold start, 30A at 115VAC, 60A at 230VAC0~+20% rated output voltage86%105%~150% constant current limiting, auto-recovery125%~150% rated output voltageI/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute-10~+60°CUL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)

1,147,161 IDR

1 Piece(s) 7 Day(s) or more 120DC24V540 ~ 125.240 ~ 125.2113.55--88~264VAC; 124~370VDCCold start, 70A at 230VAC12V: 12~14V (only for SDR-75/120), 24V: 24~28V, 48V: 48~55V91.0%Normally works within 110%~150% rated output power for 3 seconds and then shut down output voltage with auto-recovery (re-power on to recover for SDR-75) , >150% rated power or short circuit, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds14~17V for 12V model(SDR-75/120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage, re-power on to recoverI/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC (except for SDR-75)-25~+70°C (refer to output derating curve)UL508, TUV EN60950-1, GL (SDR-120/240/480) approvedEN55011(SDR-120/240/480), EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3; SEMI (SDR-75/120/240/480), GL (SDR-120/240/480)

1,898,646 IDR

1 Piece(s) 7 Day(s) or more 240DC24V1063 ~ 125.263 ~ 125.2113.510--88~264VAC; 124~370VDCCold start, 65A at 230VAC12V: 12~14V (only for SDR-75/120), 24V: 24~28V, 48V: 48~55V94%Normally works within 110%~150% rated output power for 3 seconds and then shut down output voltage with auto-recovery (re-power on to recover for SDR-75) , >150% rated power or short circuit, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds14~17V for 12V model(SDR-75/120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage with auto-recovery, or re-power on to recoverI/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC (except for SDR-75)-25~+70°C (refer to output derating curve)UL508, TUV EN60950-1, GL (SDR-120/240/480) approvedEN55011(SDR-120/240/480), EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3; SEMI (SDR-75/120/240/480), GL (SDR-120/240/480)

3,036,896 IDR

1 Piece(s) 7 Day(s) or more 480DC24V2085.5 ~ 125.285.5 ~ 125.2128.520--90~264VAC; 127~370VDCCold start, 80A at 230VAC12V: 12~14V (only for SDR-75/120), 24V: 24~28V, 48V: 48~55V94%Normally works within 110%~150% rated output power for 3 seconds and then shut down output voltage with auto-recovery (re-power on to recover for SDR-75) , >150% rated power or short circuit, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds14~17V for 12V model(SDR-75/120), 29~33V for 24V model, 56~65V for 48V model Shut down o/p voltage with auto-recovery, or re-power on to recoverI/P-O/P:3kVAC, I/P-FG:1.5kVAC, O/P-FG:0.5kVAC, O/P-DC OK:0.5kVAC (except for SDR-75)-25~+70°C (refer to output derating curve)UL508, TUV EN60950-1, GL (SDR-120/240/480) approvedEN55011(SDR-120/240/480), EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), EN61204-3; SEMI (SDR-75/120/240/480), GL (SDR-120/240/480)

Loading...

  1. 1

Basic Information

m_series_spec_item_renamed_language_6483279 DIN rail direct attachment m_series_spec_item_renamed_language_6483277 Single m_series_spec_item_renamed_language_6483283 AC/DC